The RTS-1 is an 8-port unit that can be linked with a total
of 7 units for 56 port coverage. Installation requires one RJ-31
(optional RJ-11 available) per port with one AC power supply for
all units. Operating instructions are in non-volatile memory.
Indicator lights show operating status for on-site verification.
Simple DTMF commands control the RTS-1. Any port can be used for
reaching the RTS-1. When calling in, the RTS-1 answers after a
preset number of rings. It then waits for an identity code
before giving access. Once into the RTS-1 you can move from port
to port, take lines off-hook and on-hook, and dial out using
DTMF or dial pulse. Tone prompts guide you through the usage.
Other functions include remote programming and remote
diagnostics. The unit counts how many times it was used as a
measurement of activity and for security checks.
Model RTS-1C is the control unit and is complete with the unit,
AC power supply, eight 4-pair line cords with RJ-31 or RJ-11
plugs and manual.
Model RTS-1 E is the expansion version and is complete with the
unit, ribbon cable and eight 4-pair line cords.
|
 |
99-0604AB
RTS- 1C Control Unit/ 8 Line
Vertical W/RJ11-RJ31
$799.00

99-0604-48V
RTS- 1C Control Unit/ 8 Line
Vertical W/48 V Model
$899.00
|
Applications:
-
Performs DISA (direct inward system access) function on
PBX, KTS or Centrex lines
-
Provides remote loop testing for PBX, KTS or Centrex
-
Gives remote access into C.O. switches to check equal
access, translations, software releases and billing
RTS- 1 Key Features:
-
remote access to outgoing ports
-
security code required for access
-
works with PBX, key systems and Centrex
-
acts as "remote butt set"
-
uses DTMF commands to remotely-
select outgoing port
go off-hook and on-hook
out-bound dial in both DTMF and dial pulse
detect incoming ring
change functions and check diagnostics
-
expandable from 8 to 56 ports
-
loop or ground start; RJ-31 or RJ-11
installation
Specifications:
Line Seizure: Loop or ground start
Disconnect: CPC or manual
Dialing: DTMF - 5 pps or 10 pps; Pulse - 10 pps
Bridge Loss: 0.5 dB
Power: 117 VAC, 30 watts, UL Listed
Connector: RJ-31 standard; RJ-11 optional
Physical: 10” x 8" x 1.5"; 2lbs
FCC Registration: AG997G-17336-TQ-E
Ringer Equivalence: 0.2A and 0.6B
Models: #99-0600: RTS-1 C, standard
|